Service Manual — page 50 of 715
Periodic Maintenance › Water Hose and O-ring Replacement
Text on this page
2-28 PERIODIC MAINTENANCE
Periodic Maintenance Procedures
Water Hose and O-ring Replacement
• Drain the coolant (see Coolant Change).
• Remove:
Oil Passage Cover [A]
Thermostat Housing Cover [B] (see Thermostat Re-
moval in the Cooling System chapter)
Water Pump Housing [C] (see Water Pump Removal in
the Cooling System chapter)
• Replace the hoses [D] and O-rings [E] with new ones.
• Apply grease or soap and water solution to the new O
-rings.
• Run the new hoses according to Cable, Wire, and Hose
Routing section in the Appendix chapter.
• Tighten:
Torque - Water Hose Clamp Screws: 3.0 N·m (0.31 kgf·m,
27 in·lb)
• Install the removed parts (see appropriate chapters).
• Check the
Fill the coolant (see Coolant Change).
• cooling system for leaks.